Advanced Fire Protection Designed for Sterile Environments

Cleanroom firewall construction delivers dual-purpose performance that standard fire-rated walls simply cannot match: certified life-safety protection against fire, smoke, and heat, combined with uncompromised contamination control in sterile and controlled environments. Every wall assembly must simultaneously resist flame spread for a specified duration and maintain the particle counts, pressure differentials, and surface cleanliness required by cleanroom operations.

At Get a Reno, we engineer fire-rated wall assemblies that protect both people and processes, ensuring your controlled environment stays compliant with fire safety codes and cleanroom classification standards without compromise.

Why You'll Love It

  • Contamination Control – Maintains your cleanroom classification during fire events by preserving air integrity, pressure cascades, and particle-free surfaces throughout the wall construction

  • Regulatory Compliance – Meets both building code fire safety requirements and ISO 14644 cleanroom standards simultaneously, simplifying inspection and audit processes

  • Seamless Integration – Designed to work with your existing HVAC ductwork, HEPA filtration, cable trays, and pressure systems without introducing gaps or contamination pathways

  • Minimal Disruption – Get a Reno's construction methods maintain operational cleanroom areas during installation using temporary containment zones and negative air systems

  • Long-Term Reliability – Built with chemical-resistant materials that withstand routine sterilization and decontamination processes, delivering durability and performance across years of demanding use

What Makes It Different: Meeting Code Requirements

Most standard fire walls focus exclusively on fire protection-stopping flame and heat for a rated duration. But in a cleanroom environment, a conventional wall assembly can introduce particles, outgassing compounds, or pressure leaks that compromise your entire controlled space. Fire barriers must contain fire hazards without introducing particles or outgassing risks.

Get a Reno's cleanroom fire walls are built differently:

  • Specialized Sealants – We use non-particle-generating, FDA-compatible firestop products and sealants that maintain the wall's fire rating while preserving air quality and cleanroom integrity at every penetration point

  • Pressure Differential Protection – Cleanrooms often require specific pressure cascades for air integrity and contamination control. Our systems maintain critical pressure relationships between cleanroom zones even under fire conditions, preventing smoke migration and cross-contamination

  • Chemical-Resistant Construction – Materials used in cleanroom construction must be compatible with stringent cleaning processes. Get a Reno selects non-shedding, non-porous facings and coatings-stainless steel, PVDF, and baked enamel surfaces-that withstand hydrogen peroxide vapor, peracetic acid, and bleach without degrading fire protection properties

How It Works

  1. Environmental Assessment Get a Reno evaluates your existing cleanroom classification (ISO 5 through ISO 8), pressure systems, HVAC ductwork layout, and contamination control requirements. We identify where fire compartments are needed, assess code requirements for your occupancy types, and determine the fire separation rating your building demands. Design adjustments must consider ceiling and plenum areas when integrating fire strategies in cleanrooms, and our assessment covers every transition point. Documenting material flammability test reports is essential for compliance audits, and we begin that documentation process from day one.

  2. Specialized Installation Our contractors install fire rated assemblies using cleanroom-compatible methods that maintain environmental controls throughout the project. Panels and components are prefabricated off-site to minimize on-site particle generation. We stage materials in clean zones, use protective film on surfaces, and employ containment barriers so adjacent operational spaces remain unaffected. Firewalls must maintain airtight integrity at floor, ceiling, and wall junctions-and every joint, seam, and penetration receives certified firestopping to preserve both fire rating and cleanroom seal. Specialized fire detection systems are necessary due to the unique airflow in cleanrooms, and Get a Reno coordinates these systems into the overall wall construction.

  3. Validation Testing After installation, Get a Reno provides comprehensive verification of both fire rating performance and cleanroom environmental standards compliance. This includes third-party particle count testing per ISO 14644-1, pressure differential measurement, smoke leakage assessment, and chemical emission evaluation under the recently released ISO 14644-15 (2026) standard addressing airborne chemical concentration suitability. You receive full documentation for regulatory inspection and compliance audits.

Construction Details for Fire Rated Wall Assemblies

  • Materials: Non-combustible materials are preferred for cleanroom wall construction. Get a Reno uses non-shedding gypsum board (Type X and Type C), steel studs, specialized fire rated sealants, and stainless steel framing components. Cleanroom walls must use non-shedding, non-porous materials that support rigorous sterilization. Core options include rockwool (approximately 150 kg/m³ density for superior fire resistance and insulation), aluminum honeycomb for low-outgassing microelectronics applications, and composite sandwich panels with smooth, sealed facings. Type X drywall contains about 21% chemically bound water, which releases as steam during fire exposure to slow heat transfer. Type C drywall expands when heated for enhanced fire resistance, providing an additional layer of protection in critical assemblies.

  • Fire Ratings: Get a Reno offers 1-hour, 2-hour, and 3-hour fire rated wall assemblies for different cleanroom applications. Fire rated walls resist fire for a specific time period, providing time for occupants to escape during a fire and protecting adjacent spaces. A single layer of 5/8-inch Type X drywall achieves a 1-hour rating-the most commonly specified assembly. Adding a second layer of Type X drywall can achieve a 2-hour rating. Two layers of Type X drywall on each side of steel studs achieve a 2-hour rating in standard configurations. Type X drywall typically achieves a 1-hour fire rating, and fire rated drywall is tested as part of a complete assembly to ensure every component performs together. Assemblies must comply with building regulations and achieve a fire separation rating depending on occupancy. Panel thicknesses range from 50 mm to 150 mm depending on core density and the required fire rating.

  • Asymmetric Wall Assemblies: For retrofit projects or situations where access is limited to one side, asymmetric wall assemblies provide an efficient solution. Asymmetric wall assemblies have unequal layers of gypsum board and are designed for construction from one side only. They require steel studs for construction. UL design V449 converts a 1-hour wall to a 2-hour wall, making these assemblies ideal for occupancy separations where upgrading existing fire protection is necessary without full demolition.

  • Compatibility: Works with ISO 14644 Class 5 through Class 8 cleanroom environments. Regulatory compliance in cleanroom construction includes adhering to standards such as ISO 14644, and Get a Reno ensures every assembly meets your specific classification. Our systems accommodate the stringent requirements of GMP-regulated facilities and commercial manufacturing operations.

  • Penetration Sealing: Penetrations like HVAC ducts and electrical conduits require certified firestop systems in cleanrooms. Get a Reno uses specialized firestopping solutions for cable trays, pipes, conduits, and ductwork penetrations. Maintaining the fire barrier integrity is critical for all penetrations in cleanroom walls. Firewalls in cleanrooms require constant sealing around utility penetrations to maintain integrity, and we use firestop pillows and tested sealant systems specifically formulated for cleanroom compatibility.

  • Data Centers: Data centers require firestop solutions exceeding local code requirements. European data centers often require multi-hour fire-rated coatings, and structural steel in occupied zones must withstand fire for up to four hours. Get a Reno's expertise in data center design ensures fire rated assemblies meet these elevated standards while protecting critical infrastructure and essential equipment.

  • Warranty: Get a Reno provides a 10-year performance guarantee covering both fire protection and cleanroom environmental compliance. Our commitment to code compliance and long-term performance means your investment is protected.

Who It's For: Ideal for Data Centers

Ideal for:

  • Pharmaceutical manufacturing facilities requiring sterile production areas with fire compartmentalization and GMP compliance

  • Semiconductor fabrication plants with controlled contamination environments and anti-static surface requirements

  • Biotechnology laboratories and research facilities with critical environmental controls and hazardous material occupancy separation

  • Medical device manufacturing facilities maintaining FDA compliance standards across multiple cleanroom classifications

  • Data centers requiring advanced fire protection for vital infrastructure while maintaining air quality and efficient cooling systems

If your facility demands both certified fire protection and contamination control, Get a Reno's cleanroom fire wall solutions fit your needs. Constructing firewalls in cleanroom environments means solving common challenges around fire safety and contamination control—and that balance is exactly what we deliver.

Frequently Asked Questions

Will construction disrupt our cleanroom operations? Get a Reno uses specialized construction methods to maintain cleanroom integrity during installation. We deploy temporary containment systems, negative air machines, and controlled staging to protect adjacent operational spaces. Our contractors follow strict protocols to minimize particle generation-from clean tools to protective film on every surface-so your facility continues to operate efficiently throughout the project.

How do these walls handle routine decontamination? Our fire wall systems are designed with chemical-resistant materials that withstand standard cleanroom cleaning and sterilization procedures. Whether your facility uses hydrogen peroxide vapor, bleach, isopropyl alcohol, or peracetic acid, Get a Reno selects facings and sealants that resist corrosion and degradation without compromising the wall's fire rating or surface integrity, including in utility areas where surfaces may be more exposed.

What if the system doesn't meet our cleanroom classification? Get a Reno provides comprehensive testing and certification after every installation, including particle count verification, pressure differential measurement, and smoke leakage assessment. If the installed system does not meet your specified cleanroom classification, we provide full remediation at no additional cost. Our technical support team works with you through every inspection until compliance is confirmed.

Can these walls be reconfigured or expanded later? Yes. Get a Reno's modular panel systems support future reconfiguration and expansion, allowing you to adapt your cleanroom layout as processes change. This flexibility makes our solutions ideal for growing facilities and evolving production requirements.

Do you handle both new construction and retrofit projects? Absolutely. Get a Reno has experience with both new cleanroom builds and retrofit projects within existing structures. Our asymmetric wall assemblies and prefabricated panel systems are specifically designed to integrate with existing building infrastructure, helping reduce lead concerns and making upgrades efficient and minimally disruptive. This gives buyers a practical way to address the common challenges of balancing fire safety and contamination control in cleanroom environments.

Ready to Upgrade Your Cleanroom Fire Protection?

Stop compromising between fire safety and contamination control. Get a Reno delivers cleanroom fire wall construction that protects your people, your processes, and your investment-with proven performance and a 10-year guarantee.

Call Get a Reno at (929) 294-7360 or email support@getareno.com to schedule a consultation for your next project.

Visit www.getareno.com to explore our full range of construction solutions.

Secure consultation. Expert installation. Satisfaction guaranteed.

Cleanroom Fire Wall Construction

Cleanroom Fire Wall Construction

Precio habitual  Desde $249.99
Precio de oferta  Desde $249.99 Precio habitual 
Day Rate

Have a project in mind?

Get a FREE quote instantly.

Skip the automated bots. Your project quote goes directly to a human for dedicated, personal service.

No minimum project price. We accept projects of all sizes. Big or small, we handle it all.

We think you'll love these services

Did you know you can SAVE 10% when you bundle 2 or more services?

Tu carrito
Tu carrito está vacío
¿Tienes una cuenta? Inicia sesión para pagar más rápido.
Seguir comprando Seguir comprando
Total del carrito $0.00 USD
Imagen del producto Información del producto Cantidad Total del producto